Used in ships, plants, factories, etc. for the purpose of pressure adjustment of hydraulic pump units.
Model | PA-P RA-O PA-H PA-OH |
---|---|
Fluid | Water Oil Others (Non corrosive fluid) |
Temperature | 5℃ – 80℃ (Option:150℃) |
Pressure | 0.05-1.6MPa |
Size | 3/4″ – 6″ |
Viscosity | 700cSt or less |
Body | FC200, SCPH |
Manufacturer | TAISEI KOGYO CO., LTD. |
Origin | Japan |
Size | Connection | Primary Pressure |
Pressure Control Range | CV Value |
Weight kg |
---|---|---|---|---|---|
20A(3/4″) | Connection JIS10K/20K(H) |
Primary Pressure JIS10K/ JIS20K(H) |
Pressure Control Range 1) above0.05 – 0.25MPa or less 2) above0.25 – 0.45MPa or less 3) above0.45 – 0.7 MPa or less 4) above0.7 – 1.6MPa or less (H) |
CV Value 2 |
Weightkg – |
25A(1″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 3 |
Weightkg – |
32A(1-1/4″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 6 |
Weightkg – |
40A(1-1/2″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 8 |
Weightkg – |
50A(2″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 15 |
Weightkg – |
65A(2-1/2″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 23 |
Weightkg – |
80A(3″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 30 |
Weightkg – |
100A(4″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 40 |
Weightkg – |
125A(5″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 50 |
Weightkg – |
150A(6″) | Connection JIS10K/20K(H) | Primary Pressure JIS10K/JIS20K(H) | Pressure Control Range 1) above0.05 – 0.25MPa or less2) above0.25 – 0.45MPa or less3) above0.45 – 0.7 MPa or less4) above0.7 – 1.6MPa or less (H) |
CV Value 60 |
Weightkg – |
Model No | Type | Pressure Control Range |
---|---|---|
PA-P | Internal detection | above0.05 – 0.7 MPa or less |
PA-O | External detection | |
PA-H | Internal detection | above0.7 – 1.6 MPa or less |
PA-OH | External detection |
Allowable leak rate | Less than 0.5% of CV value |
---|---|
Range ability | 20:1 |
Body | FC200/ SCPH |
・Release the excessive pressure in the piping and keep the pressure on the primary side of the valve constant.
・It is used for the purpose of pressure control of drain recovery piping, flow adjustment of pump, and pressure release of pump.
・Avoid piping in places with a lot of pulsations. There is a dedicated model for pulsations if it is absolutely necessary to install. Please contact us for details.
・The length of the external detection pipe of the primary pressure regulator should be 1 m.
・Use a speed controller or needle valve in the middle of the external detection tube.
International Sales Division +81-45-453-1616 Hours: 8:50 A.M. to 5:40 P.M.